Underfloor heating repairs, servicing and installation
Underfloor heating not working, cold in one room, or never switching off? We find the fault and put it right. Manifolds, pumps, mixing valves, actuators and thermostats repaired or replaced, systems serviced and flushed, and new underfloor heating fitted.

Oakview Plumbing and Bathrooms repairs, services and upgrades wet (water) underfloor heating across Dublin, Kildare, Laois and Offaly. If your underfloor heating is not working, is cold in one room, or will not switch off, we find the fault and fix it, usually at the manifold, without lifting the floor.
What we do with underfloor heating
- Underfloor heating repairs. Cold rooms, zones that never switch off, thermostats that drop out and pumps that run with no heat, traced back to the part causing it and fixed.
- Manifold replacement. Old or leaking manifolds replaced with new ones, with flow meters on each loop so every room gets the right amount of heat.
- Pumps and mixing valves. Underfloor heating pumps, pumping stations and thermostatic mixing valves replaced and set up.
- Actuators. The small heads on the manifold that open and close each loop, replaced when they stick or stop responding.
- Wiring centres and thermostats. Control boxes and room thermostats replaced and wired in, so each room is controlled on its own.
- Flushing and pressure testing. Each zone flushed through to clear sludge and air and check for blockages, and the system pressure tested to find leaks.
- Servicing. The pump, mixing valve, actuators, flow meters, pressure and thermostats checked, so the system keeps working.
- Balancing. Each loop set so the heat is shared evenly, and rooms that are slow to warm brought up to temperature.
- New underfloor heating. Fitted in bathrooms, kitchens and extensions, on its own or as part of a bathroom refit.
Underfloor heating not working? Common problems and how we diagnose them
Not working in one room or one zone
The actuator on that room’s loop is not opening, the room thermostat is not reaching the wiring centre, or the loop has air in it. We check whether the thermostat is calling for heat, whether the wiring centre passes the signal on, and whether the actuator opens.
Not getting hot, or cold spots on the floor
The pump, the mixing valve or the heat source is usually to blame, or there is air or sludge in the loops. We check the pump is running, measure the flow and return temperatures, check the mixing valve setting and the boiler or heat pump supplying it, and flush the loops if needed.
Always on and will not switch off
An actuator stuck open, a thermostat set too high or wired wrongly, or a wiring centre relay stuck on. We test each actuator and thermostat on its own.
Thermostat working but the floor stays cold
The thermostat is asking for heat but the signal or the water is not getting through: a failed actuator, a wiring centre fault, or a pump that is not being switched on. We follow the signal from the thermostat to the actuator and the pump.
Not working after the summer or a power cut
After months off, pumps and valves can seize and actuator pins can stick. After a power cut, wireless thermostats can lose their pairing and settings. We free or replace the pump and valves, check each actuator, and re-pair the thermostats.
Pump running but no heat reaching the floor
Often an airlock, a closed or stuck valve, or a mixing valve that will not open. We bleed and purge each loop and check every valve.
Actuators stuck open or stuck closed
Actuators wear out, and their pins stick, especially on older systems. We test each one and replace those that have failed, matched to the manifold.
Pressure dropping, or water at the manifold
Weeping valves, worn seals, loose fittings or a failed expansion vessel. We pressure test the system to find where the water is going, and repair or replace the part.
Banging, clicking or noisy pipes
Usually air in the system or a pump set too fast. We bleed the system and set the pump correctly.
Radiators working but the underfloor heating is not
If the radiators heat, the boiler is working, so the fault is in the underfloor heating: usually its pump, the mixing valve, or the wiring centre not switching the pump on.
Old systems with parts that are no longer made
On older systems, the manifold, actuators or controls may no longer be available. We tell you what can be repaired and what needs replacing, in a written quote.
Underfloor heating flushing
Over the years, sludge and air build up in underfloor heating loops, and the floor heats unevenly or not at all. We disconnect each zone from the manifold, connect it to a high-pressure water pump and flush it through until it runs clear. It also shows straight away whether a loop is blocked, which is how we rule the pipes in or out when finding a fault. Inhibitor is added afterwards to protect the system. For radiator systems, see power flushing.
Underfloor heating servicing
A service checks the parts most likely to fail before they leave a room cold: the pump, the mixing valve and its temperature, each actuator and flow meter, the system pressure and expansion vessel, the inhibitor level, and the thermostats and wiring centre.
How underfloor heating works
A wet underfloor heating system is a set of plastic pipes laid in the floor, one loop for each room or area. Warm water flows through the loops and heats the floor, and the floor heats the room.
All the loops start and finish at the manifold, usually in a hot press, utility room or under the stairs. Next to it is the pumping station: a pump that moves the water round, and a thermostatic mixing valve that keeps the water at the lower temperature underfloor heating needs.
Each loop has an actuator on the manifold. When a room’s thermostat asks for heat, the wiring centre opens that room’s actuator and switches on the pump and the boiler. When the room is warm, the actuator closes again. If any one of these parts stops working, a room, or the whole floor, stops heating.
Underfloor heating can run from an oil boiler, an electric boiler or a heat pump, with the mixing valve set to suit.
Getting the best from your underfloor heating
- Keep it steady. Underfloor heating is slow to warm up and slow to cool down. It runs best on an even temperature, turned down a couple of degrees at night rather than off.
- Give it time. After changing a thermostat, allow a few hours before deciding whether it has worked.
- Check the thermostat batteries. Wireless thermostats that lose their batteries or signal stop asking for heat, and the room goes cold.
- Run it briefly in summer. Turning the heating on for a short while every few weeks helps stop the pump and valves seizing.
- Mind the rugs. Thick rugs, underlay and large furniture sitting flat on the floor hold the heat in the floor instead of letting it into the room.
- Leave the manifold settings alone. The flow meters are set so each room gets its share of heat. Turning them can leave other rooms short.
- Look at the manifold now and then. Drips, damp patches, or a boiler pressure gauge that keeps dropping, are worth having checked early.
Underfloor heating repairs near you
We repair and service underfloor heating across South Dublin and Dún Laoghaire–Rathdown (including Tallaght, Clondalkin, Lucan, Dún Laoghaire, Blackrock and Dundrum), Kildare (Naas, Newbridge, Celbridge, Maynooth and Kildare town), Laois (Portarlington, Portlaoise and Mountmellick) and Offaly (Tullamore and Edenderry). See all the areas we cover.
If your underfloor heating is not working, get a quote or call us and we will find the fault.
How we found the fault on an underfloor heating system in Dún Laoghaire
The customer was having problems with their underfloor heating. Rooms were not heating when they should, so we carried out a full investigation of the system.
We disconnected each zone from the manifold, connected it to a high-pressure water pump and flushed it through, to check for blockages in the pipes under the floor. Every zone ran clear, so the pipes in the floor were fine. We then checked the manifold, the pump, the mixing valve and the controls. The fault was the control box. It was not sending the right signals to the actuators, and it was not picking up the information from the wireless thermostats.
The system was almost 20 years old, so rather than replace the control box alone, the customer chose to replace the whole manifold and its controls. A new manifold with flow meters, a pumping station with a Grundfos pump and an ESBE thermostatic mixing valve, Uponor actuators and a Heatmiser wiring centre went in, all wired up and tested room by room.
See the time-lapse videos belowReal job
Watch the fault finding.
Before replacing anything, each underfloor heating zone was disconnected from the manifold and flushed through with a high-pressure water pump, to check for blockages in the pipes under the floor. Every zone ran clear, which ruled out the pipework and pointed to the controls. Filmed in Dún Laoghaire, Co. Dublin, and sped up.
Real job
Watch an underfloor heating upgrade.
The old underfloor heating manifold and control box come out, and a new manifold, pumping station, thermostatic mixing valve, actuators and wiring centre go in, wired up and tested room by room, in Dún Laoghaire, Co. Dublin. Two days of work, sped up into under a minute.
What's included
Every job, priced and agreed first.
- Fault finding at the manifold, pump, mixing valve, actuators, wiring centre and thermostats
- Each zone flushed or pressure tested where blockages or leaks are suspected
- A written quote before any work starts, with a fixed price for the work described
- The parts set out in your quote, fitted and wired in
- The system filled, bled, checked for leaks and balanced
- Each zone tested with its thermostat before we leave
- Tidy work
Our work
Jobs we have completed.


FAQs
Common questions
Why is my underfloor heating not working?
The most common causes are a pump that has stopped, a mixing valve that is stuck, actuators that will not open, thermostats that have lost their connection, or a wiring centre (control box) that has failed. Air in the loops and low system pressure are also common. Almost all of these are found and fixed at the manifold, without lifting the floor.
Why is my underfloor heating not working in one room?
Usually because that room's actuator is not opening, its thermostat is not reaching the wiring centre, or the loop has air in it or is set too low on its flow meter. Each of these is checked at the manifold, so the floor rarely needs to come up.
Why is my underfloor heating always on?
Usually an actuator stuck open, a thermostat set too high or wired wrongly, or a wiring centre relay that has stuck on. We test each actuator and thermostat on its own to find which one.
Why is my underfloor heating not getting hot?
The mixing valve may be set too low or stuck, the pump may be running too slowly or not at all, or the heat source may not be supplying hot enough water. Air in the loops and sludge can also stop the floor heating evenly.
My underfloor heating stopped working after the summer. Why?
After months without running, pumps and valves can seize, and actuator pins can stick. The pump is freed or replaced, valves are freed off, and each actuator is checked.
The radiators work but the underfloor heating does not. What is wrong?
If the radiators heat, the boiler or heat source is working, so the fault is in the underfloor heating itself, usually the underfloor heating pump, the mixing valve, or the wiring centre not switching the pump on.
Can underfloor heating be repaired?
Yes. Most underfloor heating faults are in parts at the manifold, which can be repaired or replaced. The pipes in the floor very seldom fail.
Do you have to lift the floor to fix underfloor heating?
Rarely. Most faults are at the manifold, pump, mixing valve, actuators, wiring centre or thermostats, which are all reachable without lifting the floor.
How much does underfloor heating repair cost?
Heating jobs start with a €99 (excl. VAT) call-out investigation fee. If we can fix the problem on the call-out with no materials ordered, that is all you pay. If parts are needed, you get a written quotation first. See our price guide.
Can you flush underfloor heating?
Yes. Each zone is disconnected from the manifold and flushed through with a high-pressure water pump. It clears sludge and air, and shows whether a loop is blocked. Watch the flushing video, or see power flushing for radiator systems.
How do I get air out of underfloor heating?
Air is purged from each loop at the manifold, one zone at a time, with the other zones closed. It needs the system refilled and repressurised afterwards, so it is best done by a heating engineer.
Why does my underfloor heating pressure keep dropping?
Water is escaping somewhere, from a weeping valve, a fitting at the manifold or elsewhere on the system, or the expansion vessel has failed. A pressure test finds where. See expansion vessels.
Does underfloor heating need servicing?
A regular check keeps it working well. A service covers the pump, mixing valve, actuators, flow meters, system pressure, inhibitor and thermostats, and catches small problems before a room goes cold.
Why does underfloor heating take so long to warm up?
The heat has to warm the floor itself before you feel it in the room, which can take a few hours. That is normal. It works best kept on a steady, even temperature rather than switched fully on and off.
What does the mixing valve do?
Underfloor heating runs on cooler water than radiators. The thermostatic mixing valve mixes hot water from the boiler with cooler water coming back from the floor, so the floor gets water at the right temperature.
My system is old. Should I repair it or replace the manifold?
If one part has failed, it is repaired or replaced on its own. If several parts are worn, parts are no longer made, or the controls keep failing, replacing the manifold, pump and controls together is often the better choice. You get a written quote for either, so you can decide.
Is underfloor heating a job for a plumber or an electrician?
Usually a plumber. The manifold, pump, mixing valve, actuators, wiring centre and thermostats are all heating work, and most underfloor heating controls are powered from a spur switch, which a qualified plumber can work on. Where new electrical circuits are needed, Oakview uses its own registered electrician.
Do you work on electric underfloor heating mats?
No. Oakview works on wet (water) underfloor heating only, the kind with pipes in the floor and a manifold. We do not install or repair electric underfloor heating mats.
Can underfloor heating run from an oil boiler, electric boiler or heat pump?
Yes. The manifold and mixing valve are set up to suit the heat source. See electric boilers and oil boilers.
Can you add underfloor heating to a bathroom refit or an extension?
Yes. New underfloor heating is fitted as part of a bathroom refit or on its own, and set out in your quote.
Do you work on underfloor heating someone else installed?
Yes. Underfloor heating is repaired, serviced and upgraded whoever installed it.
Where do you repair underfloor heating?
Across Dublin (South Dublin and Dún Laoghaire–Rathdown), Kildare, Laois and Offaly, from our base in Portarlington. See the areas we cover.
Call-out investigation fee €99 (excl. VAT)
Get a quote
Tell Ryan about the job and he will arrange a site visit and a written quote. Phone lines are open Mon–Fri 09:30–17:00.
Oakview covers Laois, Offaly, Kildare, South Dublin and Dún Laoghaire–Rathdown from Portarlington. See the areas we cover.
If we can fix the problem on the call-out with no materials ordered, all you pay is the €99 (excl. VAT). If not, we will give you a written quotation on the call-out.